RCC jacketing increases the dimensions of the selected member through the addition of a designed reinforced section. Its effectiveness depends on the structural design, the connection between the existing and new materials, detailing and execution.
RCC jacketing is not a cosmetic surface repair. It is a structural intervention that requires appropriate engineering assessment and design.
Jacketing may be specified where an existing concrete column requires increased capacity or rehabilitation.
Selected deteriorated concrete members may require a strengthening solution alongside concrete repair.
Where a building undergoes an alteration or change in use, structural evaluation may identify elements that require strengthening.
Members affected by particular types of damage may be considered for strengthening after the extent of damage and the structural implications have been assessed.



The required jacket dimensions, reinforcement and connection details must be established by the responsible structural engineer.
The original concrete surface is prepared as specified to support the interface between the existing member and the new jacket.
The reinforcement arrangement and connection details are implemented according to the approved design.
The new jacket is formed and filled using the specified concrete or compatible material system.
The completed work is cured and reviewed according to the project requirements.
RCC Jacketing Requires Planned Execution
Review the condition and intended performance of the existing member.
Obtain the required engineering assessment and strengthening design.
Prepare the existing concrete and expose reinforcement only as specified.
Install the reinforcement and connections according to approved drawings.
Complete formwork and place the specified concrete or repair material.
Carry out curing, inspection and completion activities as required.
Its purpose is to strengthen or rehabilitate selected existing structural elements by adding a designed reinforced concrete section around them.
No. Suitability depends on the column’s condition, structural role, damage, foundation and overall design requirements. A qualified structural engineer must determine the appropriate strengthening method.
No. Concrete repair addresses damaged or deteriorated areas. RCC jacketing is a structural strengthening technique, although repair work may form part of the overall project.
Discuss the affected structural element and project requirements with Naturoprotect to coordinate the appropriate repair and application discussions.